XS PC 50 VioLab Bench Multiparameters

Professional bench multiparameter with innovative high definition color LCD display, with possibility of brightness adjustment.
Measurement of pH, mV, ORP, Conductivity, TDS, with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

PC50-60_VioLab.pdf
PDF Manual

Measuring range:
pH: 0.00 … 14.00 (0.01 pH)
mV: -1000 … +1000 (0.1 mV)
Cond: 0.0 µS … 200 mS (0.01 µS – automatic)
TDS: 0.01 mg/l … 200 g/l
Temperature: 0 … 100.0 °C (0.1 °C)

Supplied as standard:
Electrode holder stand, colored buffer solutions, power supply and instructions for use.

 

XS PC 50 VioLab multiparametro da banco – Elettrodo 201T DHS – Cella 2301 T

XS PC 50 VioLab Bench Multiparameter – Elettrode 201 T – Cell 2301 T

XS PC 50 VioLab Bench Multiparameter – Cell 2301 T – Without electrode

Data sheet

Features Values
Accuracy (Cond) ±2 % f.s.
Accuracy (pH) ±0.02 pH
Accuracy (Temperature) ±0.5 °C
Power supply 100 – 240 V
Temperature calibration Yes
Temperature coefficient (max) 0.00 … 10.00 % / °C
DHS compatibility Yes
Temperature compensation 0.00 … 80.0 °C
Cell constant 0.1 / 1 / 10
Criteria for stability of the measure Low – Med – High (pH)
Dimensions 160 x 140 x 45 mm
Display High-definition, backlit color LCD
TDS factor 0.40 … 1.00
Warranty 3 years
IP rating 54 IP
Buffer used indication Yes with icons
Selectable languages BNC – RCA
Name PC 50 VioLab
Regulations CE
Parameters pH, mV, ORP, Conductivity, TDS, Temperature
Weight 0.38 kg
Calibration points (Cond) 1 … 4
Calibration points (ORP) 1
Calibration points (pH) 1 … 3 automatic values – 2 user values
Measuring range (Cond) 0.00 µS … 200 mS
Measuring range (mV ORP) -1000 … +1000 mV
Measuring range (pH) 0 … 14 pH
Measuring range (TDS) 0.1 mg/l … 200 g/l
Measuring range (Temperature) 0.0 … +100.0 °C
Resolution (Cond) 0.01 / 0.1 / 1 µS/cm (automatic scale)
Resolution (ORP) 1 mV
Resolution (pH) 0.01 pH
Resolution (Temperature) 0.1 °C
Recognized conductivity buffers 84 µS – 147 µS – 1413 µS – 12.88 mS – 111.8 mS – 1 user value
Recognized pH buffers USA – NIST – 2 custom values
Working temperature 0 … +45 °C
Reference temperature +15 … +30 °C
Cell type 2 rings

Check other products

Ask us anything

We will answer a soon as posible.